Updated Software for the Optimeter, SmartOTDR, T-BERD/MTS Instruments (July 2022 release)

VIAVI has released updated software for the Optimeter, SmartOTDR, T-BERD/MTS-2000 and -4000 V2.

The latest software release includes several usability enhancements, these are the main new functional additions, for more information please see the release notes:

 

FiberComplete PRO for T-BERD/MTS-2000 V2, -4000 V2, and OneAdvisor 800 Fiber

True bi-directional fiber certification solutions to improve fiber technician efficiency, driving operational excellence with FiberComplete PRO (formerly TestPRO)

 

Guided and automated referencing for MPO test cables

  • Avoid risk of human errors with animated icons to instruct/guide with the referencing process
  • Reduced setup time and increased result accuracy with integrated IL and ORL referencing for MPO test cords

Support for high fiber count projects with integration of Cable-SLM and MPO switch module with FiberComplete PRO

  • Track large projects with no need for separate spreadsheets, support for fiber counts up to 9996 (833 x 12MPO)
  • Reduce test time for multi-fiber and MPO bundles with automatic sequencing of bi-directional test (including TrueBIDIR OTDR analysis) with no manual switching between fibers
  • Manage project progress with Cable and SmartGrid views showing pass/fail status

MPO polartity mapper

  • Complete work on time and avoid wasted test sequences by mapping and confirming the MPO polarity of a link (A, B, C) prior to beginning test
  • Enable rework of multi-fiber and MPO links while still on-site to avoid future site revisits

Instruments/mainframes (Optimeter, SmartOTDR, T-BERD/MTS-2000 V2, and -4000 V2)

Secure you instrument with pincode protection option

  • Instruments are securely locked if lost or stolen, preventing further use or access to stored data/information

Modernized Job Manager

  • Faster familiarization and easier switching between test functions and optical fibers
  • Real time view of work/job progress via Mobile Tech App

OTDR

Support for Data Center Interconnect fiber type

  • Easier setup with new predefined specs for G654E fiber

StrataSync v13.5 Release notes here:

Here are the release notes for Stratasync v13.5: ( Also available in the Stratasync Help page)

 

StrataSync 13.5 Release Notes 022622

StrataSync services on the US and EURO Server will be unavailable on Saturday, February 26th, from 00:01 until 6:00 AM EST (UTC-5) ( 0501 until 1100 UTC )

Please be advised that StrataSync services on the US and EURO Server will be unavailable on Saturday, February 26th, from 00:01 until 6:00 AM EST  (UTC-5)

( 0501 until 1100 UTC )

 

 

The following web functions, reports,  and Instrument synchronization services will be unavailable during this maintenance window.

 

  • {VIAVI test instrument synchronization with StrataSync/CERTiFi accounts} 
  • {VIAVI test instrument synchronization with StrataSync via Mobile Tech Application} 
  • {StrataSync and CERTiFi web user interface} 
  • {StrataSync APIs/external interfaces} 
  • {StrataSync scheduled and notification emails, including saved views and reports} 
  • {StrataSync Reports} 
  • {StrataSync Analytics dashboards} 
  • {StrataSync data exchange links} 

 

 

During this period StrataSync will be upgraded to release version 13.5.

StrataSync 13.5 is a standard release that will contain new functionality, performance enhancements, and bug fixes.

 

 

The release notes for StrataSync Release 13.5 will be sent to this address group when available.

A link to the 13.5 Release notes will be also posted on “What’s New” in the StrataSync application.

 

Please plan accordingly.

 

Thank you,

StrataSync Engineering and Operations Team

Release Notes for StrataSync Release 13.0 ->Here:

Below is a link to the StrataSync V 13.0 release notes:

StrataSync 13.0 Release Notes 120321

StrataSync R 13.0 Release Notes

 

Your attention please:StrataSync services on the US and EURO Server will be unavailable on Saturday, December 4th, from 00:01 until 6:00 AM EST (UTC-5)

Your attention please:

 

Please be advised that StrataSync services on the US and EURO Server will be unavailable on Saturday, December 4th, from 00:01 until 6:00 AM EST  (UTC-5)

( 0501 until 1100 UTC )

The following web functions, reports,  and Instrument synchronization services will be unavailable during this maintenance window.

  • {VIAVI test instrument synchronization with StrataSync/CERTiFi}
  • {VIAVI test instrument synchronization with StrataSync via Mobile Tech Application}
  • {StrataSync and CERTiFi web user interface}
  • {StrataSync APIs/external interfaces}
  • {StrataSync scheduled and notification emails, including saved views and reports}
  • {StrataSync Reports}
  • {StrataSync Analytics dashboards}
  • {StrataSync data exchange links}

During this period StrataSync will be upgraded to release version 13.0.

StrataSync 13.0 is a standard release that will contain new functionality, performance enhancements, and bug fixes.

A link to the 13.0 Release notes will be also posted on “What’s New” in the StrataSync application.

 

Please plan accordingly.

 

Thank you,

StrataSync Engineering and Operations Team